Full SN EN 12464-1 Room List
Please select
Agricultural Buildings for Livestock (50 lux @ Floor)
Agricultural Loading, Handling and Machinery (200 lux @ Floor)
Airport Arrival and Departure Halls (200 lux @ Floor)
Airport Passport Control (500 lux @ 1.1m)
Animal Feed Preparation: Dairy, Utensil Washing (200 lux @ 0.75m)
Archiving and Document Store (200 lux @ 0.75m)
Area in Front of Lifts, Elevators and Escalators (200 lux @ Floor)
Automated Zones - Unmanned (75 lux @ Floor)
Baking - Finishing, Glazing, Decorating (500 lux @ 0.75m)
Boiler House (100 lux @ Floor)
Building Entrance with Canopy (30 lux @ Floor)
Cabling and Wire Manufacture (300 lux @ 0.75m)
CAD Work Stations (500 lux @ 0.75m)
Canteens and Break Areas (200 lux @ Floor)
Cellars (50 lux @ Floor)
Cement and Brickwork - Rough Forms (300 lux @ 0.75m)
Cement Drying (50 lux @ Floor)
Central Logistics Corridor - Heavy Traffic (300 lux @ Floor)
Ceramics Drying (50 lux @ Floor)
Ceramics Preparation, General Machine Work (300 lux @ 0.75m)
Cleaner's Cupboard (200 lux @ Floor)
Cloakroom, Washrooms, Bathrooms, Dressing, Lockers, Shower, Sink (200 lux @ Floor)
Coil Impregnating (300 lux @ 0.75m)
Cold Store Room (300 lux @ Floor)
Colour Inspection (1000 lux @ 0.75m)
Colour Inspection in Multicoloured Printing (1500 lux @ 0.75m)
Configuration and Rehandling (750 lux @ 0.75m)
Constantly Manned Work Stations in Processing Installations (300 lux @ 0.75m)
Corridors and Circulation Areas (100 lux @ Floor)
Cutting and Sorting of Fruits and Vegetables (300 lux @0.75m)
Cutting, Finishing, Inspection (750 lux @ 0.75m)
Demonstration Tables in Auditoriums (750 lux @ 0.75m)
Despatch, Picking and Packing Area (300 lux @ Floor)
Die Casting (300 lux @ Floor)
Dispatch Packing Handling Areas (300 lux @ Floor)
Dressing Room (300 lux @ 0.75m)
Ear Examination Room (1000 lux @ 1.2m)
Educational Art Rooms (750 lux @ 0.75m)
Educational Auditorium or Lecture Hall (500 lux @ Floor)
Educational Classroom and Tutorial Room (500 lux @ 0.75m)
Educational Classroom for Adults and Evening Classes (500 lux @ 0.75m)
Educational Computer and Music Practice Room (300 lux @ 0.75m)
Educational Handicraft Room (300 lux @ 0.75m)
Educational Kitchen (500 lux @ 0.75m)
Educational Play Room or Nursery (300 lux @ Floor)
Educational Practical Room or Laboratory (500 lux @ 0.75m)
Educational Preparation Room or Teaching Workshop (500 lux @ 0.75m)
Educational Sports Hall, Gymnasium or Swimming Pool (300 lux @ Floor)
Educational Teachers Room (300 lux @ 0.75m)
Electrical Assembly Work - Fine (750 lux @ 0.75m)
Electrical Assembly Work - Medium (500 lux @ 0.75m)
Electrical Assembly Work - Precision (1000 lux @ 0.75m)
Electrical Assembly Work - Rough (300 lux @ 0.75m)
Electronic Workshops, Testing, Adjusting (1500 lux @ 0.75m)
Elevators, Lifts (100 lux @ Floor)
Enamelling, Rolling, Pressing, Shaping Simple Parts, Glazing, Glass Blowing (300 lux @ 0.75m)
Entrance Hall or Lift Lobby (200 lux @ Floor)
Filing, Copying (300 lux @ 0.75m)
Fine Assembly Workshop (750 lux @ 0.75m)
Food Industry Colour Inspection (1000 lux @ 0.75m)
Food Laboratories (500 lux @ 0.75m)
Foundry and Metal Work Casting and Machine Moulding (200 lux @ Floor)
Fuel Supply Plant (50 lux @ Floor)
Fully Enclosed Train Platform - Multiple Passengers (200 lux @ Floor)
Galvanizing (300 lux @ 0.75m)
Gangways: Manned (150 lux @ Floor)
General Bulk Storage Warehouse (200 lux @ Floor)
General Cleaning (100 lux @ Floor)
General Dentist Lighting (500 lux @ 0.85m)
General Eye Test Area (500 lux @ 1.2m)
General Machine Work (300 lux @ 0.75m)
General Retail Sales Area (300 lux @ Floor)
Grinding of Optical Glass, Crystal, Hand Grinding and Engraving (750 lux @ 0.75m)
Grinding, Engraving, Glass Polishing, Shaping Precision Parts, Manufacture (750 lux @ 0.75m)
Hairdressing (500 lux @ 1.2m)
Hand and Core Metal Moulding (300 lux @ Floor)
Health Care Day Room (300 lux @ 0.75m)
Health Care Waiting Room (200 lux @ 0.75m)
Hospital Examination and Treatment Room (1000 lux @ 0.85m)
Hospital Multi Purpose Corridor or Waiting Room (200 lux @ 0.85m)
Hospital Staff Office, Pharmacy or Laboratory (500 lux @ 0.75m)
Hospital Ward, Staff Room, Sterilisation or Disinfection Room (300 lux @ 0.85m)
Indoor Car Park (75 lux @ Floor)
Industrial Loading Bay or Ramp (150 lux @ Floor)
Inspection of Glasses and Bottles, Trimming, Sorting etc. (500 lux @ 0.75m)
Larder (200 lux @ Floor)
Laundry Goods In, Washing, Dry Cleaning, Ironing and Pressing (300 lux @ 0.75m)
Laundry Inspection and Repairs (750 lux @ 0.75m)
Leather Work - Fleshing, Tumbling of Skins etc. (300 lux @ 0.75m)
Leather Work - Quality Control and Colour Inspection (1000 lux @ 0.75m)
Leather Work - Vats, Barrels, Pits (200 lux @ 0.75m)
Library Bookshelves (200 lux @ Floor)
Library Reading Areas (500 lux @ 0.75m)
Lithography (1000 lux @ 0.75m)
Loading Ramps and Bays (150 lux @ Floor)
Manufacture of Delicatessen Food, Kitchen Work, Cigar Manufacture etc. (500 lux @ 0.75m)
Manufacture of Jewellery (1000 lux @ 0.75m)
Marquetry (750 lux @ 0.75m)
Medical Examination or First Aid Room (500 lux @ Floor)
Metal and Foundry Platforms (100 lux @ Floor)
Metal Casting Sand Preparation (200 lux @ Floor)
Metal Model Building (500 lux @ 0.75m)
Metal Scribing, Tool Making and Surface Preparation (750 lux @ 0.75m)
Metal Tooling, Jig Making, Precision and Micro-Mechanics (1000 lux @ 0.75m)
Open Die Metal Forging (200 lux @ 0.75m)
Open Goods Storage (200 lux @ Floor)
Packing and Grouping Area (300 lux @ 0.75m)
Paper Based Meeting or Conference Room (500 lux @ 0.75m)
Paper Based Office (500 lux @ 0.75m)
Paper Based Training or Board Room (500 lux @ 0.75m)
Paper Cutting and Hand Printing (500 lux @ 0.75m)
Paper Manufacture and Processing (300 lux @ 0.75m)
Parking Areas - Open to Public (150 lux @ Floor)
Pharmaceutical Production (500 lux @ 0.75m)
Plant Rooms, Switch Gear Rooms (200 lux @ Floor)
Plate Machining (200 lux @ 0.75m)
Post Sorting, Switchboard (500 lux @ 0.75m)
Power Station Control Rooms (500 lux @ 0.75m)
Power Station Machine Halls and Side Rooms (200 lux @ Floor)
Precision Assembly Workshop (1000 lux @ 0.75m)
Precision Machining, Grinding with <0.1mm tolerances (500 lux @ 0.75m)
Precision Measuring Rooms, Laboratories (500 lux @0.75m)
Precision Work - Decorative Grinding, Hand Painting (1000 lux @ 0.75m)
Preparation and Baking (300 lux @ 0.75m)
Preparation of Materials: Work on Kilns and Mixers (200 lux @ 0.75m)
Processing Installations with Limited Manual Intervention (150 lux @ 0.75m)
Production Plants with Continuous Manual Operation (200 lux @ 0.75m)
Production Plants without Manual Operation (50 lux @ Floor)
Rack Storage - Floor (150 lux @ Floor)
Reception Desk (300 lux @ 0.75m)
Remote-operated Processing Installations (50 lux @ 0.75m)
Residential Bedroom or Toilet (100 lux @ Floor)
Residential Kitchen Room (200 lux @ 0.75m)
Residential Lounge or Dining Area (150 lux @ Floor)
Resting Rooms (100 lux @ Floor)
Retail Dressing or Fitting Room (300 lux @ Floor)
Retail Storage Area (300 lux @ Floor)
Retail Till Area (500 lux @ 0.75m)
Retail Wrapping Table (500 lux @ 0.75m)
Rooms for Medical Attention (500 lux @ Floor)
Rooms for Physical Exercise (300 lux @ Floor)
Rough and Average Machining with >0.1mm tolerances (300 lux @ 0.75m)
Rough Assembly Workshop (300 lux @ 0.75m)
Saddlery Work, Show Manufacture, Stitching, Sorting, Leather Dyeing (500 lux @ 0.75m)
School Canteens (200 lux @ 0.75m)
Screen Based Meeting or Conference Room (300 lux @ 0.75m)
Screen Based Office (300 lux @ 0.75m)
Screen Based Training or Board Room (300 lux @ 0.75m)
Seating Areas in Auditoriums (200 lux @ Floor)
Sewing, Fine Knitting and Manual Design (750 lux @ 0.75m)
Sheet Metalwork <5mm (300 lux @ 0.75m)
Shoe and Glove Making (500 lux @ 0.75m)
Sick Animal Pens: Calving Stalls (200 lux @ Floor)
Sick Bay (500 lux @ Floor)
Sorting and Washing of Food Products - Milling, Mixing, Packing (300 lux @ 0.75m)
Stairs in Educational Buildings (150 lux @ Floor)
Stairs, Escalators, Travelators (100 lux @ Floor)
Standard Bookbinding (500 lux @ 0.75m)
Steel and Copper Engraving (2000 lux @ 0.75m)
Steel Testing (500 lux @ 0.75m)
Stockrooms for Teaching Materials (100 lux @ Floor)
Stores and Stockrooms (100 lux @ Floor)
Student Common Rooms and Assembly Halls (200 lux @ Floor)
Surveillance Station (300 lux @ Floor)
Technical Drawings Room (750 lux @ 0.75m)
Textile Drying Room (100 lux @ Floor)
Textile Fabric Printing, Spinning, Warping, Reeling and Winding (500 lux @ 0.75m)
Ticket Office (200 lux @ 0.75m)
Toilet, Bathroom or Washroom (200 lux @ Floor)
Trade Fair General Area (300 lux @ Floor)
Tyre Production (500 lux @ 0.75m)
Unloading and Loading Area (200 lux @ 0.75m)
Vehicle Body Work and Assembly (500 lux @ Floor)
Vehicle General Services, Repair and Testing (300 lux @ Floor)
Vehicle Inspection (1000 lux @ 0.75m)
Vehicle Painting and Inspection (750 lux @ Floor)
Watch Making - Automatic (500 lux @ 0.75m)
Watch Making - Manual (1500 lux @ 0.75m)
Welding (300 lux @ 0.75m)
Winding - Large Coils (300 lux @ 0.75m)
Winding - Medium-sized Coils (500 lux @ 0.75m)
Winding - Small Coils (750 lux @ 0.75m)
Wood Work Quality Control and Inspection (1000 lux @ 0.75m)
Wood Working Machine Operation (500 lux @ 0.75m)
Work at Joiner's Bench, Gluing and Assembly (300 lux @ 0.75m)
Work Stations - Breweries, Food Manufacture etc. (200 lux @ 0.75m)
Work Stations and Critical Zones in Slaughter Houses, Butchers etc. (500 lux @ 0.75m)
Working with Precious Stones (1500 lux @ 0.75m)
Writing, Typing, Reading, Data Processing (500 lux @ 0.75m)